We do not decide
Why bramaguard has no failover moment at all, and where the idea comes from.
A link dies, or a robot walks out of Wi-Fi range and onto LTE. What happens next, in anything built around failover, is a loop: notice the failure, decide where the traffic should go, move it. Detect, decide, switch. The engineering goes into making each step fast — a shorter probe interval, a smarter policy, a quicker handover — and the published figures land somewhere between a few hundred milliseconds and a few seconds.
That loop has two costs. The obvious one is the time: whatever was in flight during those seconds is gone, and a call, a control stream or a video feed notices. The less obvious one is that the loop is a component. Something has to run the detection, hold the policy and execute the switch, which means something can be late, be wrong, or fail on its own — and it usually fails exactly when the network around it is already misbehaving.
The loop is not there
Bramaguard sends every packet over every active link at the same instant. The far end keeps whichever copy arrives first; the later one lands in the kernel's own anti-replay window and is dropped. When a link dies, the copy of the packet that was crossing it is already halfway along another link — so there is nothing to detect, nothing to decide and nothing to switch. A fiber break costs zero lost seconds and a gap of 0.168 s at ten packets a second — where a detect-decide-switch loop costs whole ones.
What does happen on a link failure is bookkeeping. The kernel tells us through netlink in two to eight milliseconds, and the path leaves the active set before the next packet is laid down. Nobody was waiting for that message. The traffic had already survived.
That is the whole of the reliability story: zero added bytes and zero lost seconds when a link fails, with delay, loss, jitter and reordering on every link.
The same answer, in a heart
The same answer appears in a system that has been under harder constraints for a lot longer.
A heart has no failover controller. Nothing in it notices that the primary pacemaker has stopped and promotes a backup: every level of the conduction system runs its own rhythm continuously, and the faster one simply suppresses the slower. The backup is never triggered — it is un-suppressed. Biology skipped the detect-decide-switch loop for the reasons we did: a controller that decides costs time, and it is a single point of failure in the one place you cannot afford one.
That is where the analogy ends. The principle stays: do not decide.
Where this sits
Duplication is not our invention — bonding appliances have done it for years, on their own hardware and with their own protocol. What we do is duplicate in software, on hardware you already own, with the cryptography left in the kernel. You can check that on your own links.